G-Class Product Specs CD-45GV-50, CD-45G-50-Pro

Product Specs, Features and Dimensional Drawing for:

CD-45GV-50, CD-45G-50-PRO Specs, Doc# 4-1318-01 Rev.D

 

Click download for more information.

 

OZONE OUTPUT (+/-10%)……….. 45 g/hr

FLOW RATE (max)……………30 scfh (14.1 lpm)

CONCENTRATION…………… 4.0 % weight

POWER REQUIREMENTS……….. 230 VAC, 50 Hz, 1Ø, 8 Amp*

COOLING WATER

FLOW………………………….. 0.2 gpm (0.8 lpm)

INLET TEMPERATURE**…….50°F – 90°F (10°C – 32°C)

INLET PRESSURE……………15 – 40 psi (100 – 270 kPa)

HEAT REJECTION………………. 4550 BTU/hr (1.3 kW)

WEIGHT……………………………. 175 lb (79 kg)

LOCATION REQUIREMENTS***

MOUNTING………………….. FLOOR OR WALL MOUNT IN A CLEAN, PROTECTED AREA USING BRACKETS PROVIDED.

AMBIENT TEMPERATURE… 40°F – 100°F (5°C – 38°C)

VENTILATION……………….. 6 AIR CHANGES PER HOUR (MIN)

 

* STEADY STATE CURRENT. START-UP CURRENT WILL MOMENTARILY EXCEED THIS VALUE. 15A BREAKER RECOMMENDED.
** POTABLE WATER MAY BE USED FOR COOLING. SPECIFIED OZONE OUTPUT IS AT 70°F. GENERATOR EFFICIENCY AND LIFE WILL BE IMPROVED WITH WATER INLET TEMPERATURES OF 80°F OR LESS.
*** PROTECTION FROM WEATHER MUST BE PROVIDED FOR OUTDOOR INSTALLATIONS. OPERATING OUTSIDE OF THE RECOMMENDED TEMPERATURE RANGES MAY RESULT IN DAMAGE NOT COVERED UNDER THE MANUFACTURER’S WARRANTY.